Chinese
		
		
	Specification:
| 
			 Model No  | 
			
			 HPS-510  | 
		|
| 
			 Output  | 
			
			 DC Voltage  | 
			
			 13.8V  | 
		
| 
			 Rated Current  | 
			
			 25A  | 
		|
| 
			 Current Range  | 
			
			 0-30A  | 
		|
| 
			 Rated Power  | 
			
			 350W  | 
		|
| 
			 Ripple & Noise Max  | 
			
			 100mVp-p  | 
		|
| 
			 Voltage Precision  | 
			
			 ±1.0%  | 
		|
| 
			 Line Regulation  | 
			
			 ±0.2%  | 
		|
| 
			 Load Regulation  | 
			
			 ±0.2%  | 
		|
| 
			 Startup, Rising, Keeping Time  | 
			
			 200ms 80ms 20ms  | 
		|
| 
			 Input  | 
			
			 Voltage Range  | 
			
			 220VAC±20%  | 
		
| 
			 Frequency Range  | 
			
			 47-63Hz  | 
		|
| 
			 Efficiency  | 
			
			 ≥82%  | 
		|
| 
			 AC current  | 
			
			 2.2A/220VAC  | 
		|
| 
			 Leakage Current  | 
			
			 <1mA/240VAC  | 
		|
| 
			 Protection  | 
			
			 Over Load  | 
			
			 When the current load exceeds 32-33A, the overcurrent protection is activated.  | 
		
| 
			 Protection mode: when rapid decline in voltage, and current revert under current range, it will resume automatically  | 
		||
| 
			 Environment 
  | 
			
			 Operation Temperature, Humidity  | 
			
			 -10~+45℃ 20~90%RH  | 
		
| 
			 Storage Temperature, Humidity  | 
			
			 -20~+85℃ 10~95%RH  | 
		|
| 
			 Temperature Coefficient  | 
			
			 ±0.03﹪/℃(0~50℃)  | 
		|
| 
			 Vibration  | 
			
			 By X,Y,Z axes,10~500HZ,2G 10min/period,total 60minutes  | 
		|
| 
			 Safety and Battery  | 
			
			 Safety Codes  | 
			
			 Comply with UL1012  | 
		
| 
			 Compression Strength  | 
			
			 I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  | 
		|
| 
			 Insulation Resistance  | 
			
			 I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 70﹪RH  | 
		|
| 
			 Electromagnetic Interference(EMI)  | 
			
			 Comply with FCC Part 15j Conduction Class B  | 
		|
| 
			 Others  | 
			
			 MTBF  | 
			
			 322.4K hrs min.MIL-HDBK-217F(25℃)  | 
		
| 
			 Dimension  | 
			
			 310*482*88mm(L*W*H)  | 
		|
| 
			 Packing  | 
			
			 5Kg Pc/bo×1pc  | 
		|
| 
			 Remarks  | 
			
			 1. If it's in the absence of special note, all of the specifications are measuring in the following conditions: Input 230VAC, Rated load, 25°C of temperature. 2. Ripple and Noise measurement: use a Twisted-Pair of 12", and the terminal must parallel the capacity of 0.1uF and 47UF at the same time. measuring under 20MHZ wideband. 3. Precision: It contains set errors, Linear regulations and Load regulations.  | 
		|